The ST5120 hand-held Field Strength Meter uses RF signal processing techniques in
combination with microprocessor technology to produce quick and accurate signal
measurements. The meter provides the user a choice of reading individual channel video,
audio, or a-a power level measurements. Automatic/semi-automatic internal calibration
corrects for measurement variations due to frequency response, temperature change and
internal attenuator setting. The combination of keypad tuning and menu driven display
allow for simple operation.

The meter is programmed with both USA CATV and UHF/UHF NTSC standard formats.
Users can also select frequencies for signal testing. The backlit LCD allows for viewing
signal measurements even in dark places.

Specifications

Input

Frequency

Range 46-870

MHz

Channels 2 – 135 CATV
Channels 2 – 78 Off – Air
Frequency

Stability

 30 ppm

Resolution

50

KHz

Input

Impedance

75

Power Level Testing

Range

-35

-

+60

dBmV

Accuracy

± 2.5 dBmV

Resolution

0.1

dBmV

AC Voltage Testing

Input

Range

10

100

vac

Channel

Type

NTSC

(6

MHz)


Input

Connector

Replaceable High Return Loss F Type

LCD

Controls

Contrast,

Back

Lighting

Screen

Size

60

*

17

mm

Features

Audio

Adjustable

Volume

Illumination

Back-Lit

LCD

AC

Input

110V

/

60Hz

Battery

use

8

Hours

Minimum

Charge

Size

(mm)

210

*

93

*

50

Weight

0.5

Kg