Chapter 3 operation procedure – Holland Electronics NE 1101L User Manual

Page 10

Advertising
background image

- 10 -

Forward Optical Receiver

Operation Manual

Chapter 3 Operation Procedure

The following are procedures for the normal operation of the FRx:

1) Switch the AC Power switch located on the rear panel to the ON position; the LED indicator for [POWER] on the

front panel will light up to indicate AC Power is connected.

2) Inspect the front panel [Ch A Loss] LED indicator.

Operation range of optical input power is from –6dBm to +3dBm , when the optical power large than –3dBm ,

the Output RF level could reach the default output level 96dBuV per channel when 77 channel load and

OMI=3.6%.

Under normal conditions, the LED should be off.

A flashing red light indicated abnormal Optical operation that can be caused by:

a) Ch A Optical Input Power lower than optical loss threshold.

b) Receiver module inside of the FRx work abnormally.

3) Inspect the [RF Loss] LED indicator.

Under normal conditions, the LED should be off.

A flashing red light indicates abnormal RF Output conditions, usually low output signal level.

4) Inspect the [Auto Gain Ctrl] LED indicator.

OFF: Operating in MGC Mode

Green: Operating in AGC Mode

Note: 1.There is two modes on AGC operation, one is detect Pilot signal, and

other is composite RF power feedback control. Before operation, please

select the AGC mode on “SETTING” menu.

2.Pilot tone mode used with Pilot Tone 10.7MHz ±100KHz coming from the

Transmitter. If there is no this feature in transmitter, please select RF

AGC or MGC control mode.

5) Check Optical Input Power in the LCD panel, 0 dBm is recommended.

6) Adjust the RF output level by using the front panel [SETTING] page. RF power operate in 96dBuV per channel

when 77 channel which have flat frequency response , if Channel number is higher , user could operate

lower

RF

level per channel .Keep the total composite power to maintain the distortion performance .