Dmx linking, Dmx modes, Signal wiring – ILUMINARC Ilumipod™ Inground Tri-12 IP User Manual

Page 14: Protocol connectivity, Installation

Advertising
background image

Installation

10

Ilumipod Inground Tri-12 IP Optic WW User Manual Rev. 3

The Ilumipod
Inground Tri-12
IP Optic WW
must be linked

using DMX cable in a
daisy chain (serial)
fashion. To comply with
the EIA-485 standard, no
more than 32 products
should be connected on
one daisy chain without
using a DMX optically
isolated splitter. Doing
otherwise may result in
deterioration of the digital
DMX signal.

USITT
recommends
limiting the total

length of the DMX cable
(from the first
product/controller to the
last) to 300–455 m
(985–1,500 ft).

Disconnect the
product from the
AC power before

opening it.

The signal cable
must match or
exceed the

electrical characteristics
of the Belden® 9841
cable for EIA RS-485
applications. You may
also use CAT5, 5e, or
CAT6 LAN cable.

DMX Linking

You may link the Ilumipod Inground Tri-12 IP Optic WW to a DMX controller using a
standard DMX serial connection. If using other DMX products compatible with the Ilumipod
Inground Tri-12 IP Optic WW, you can control each individually with a single DMX
controller.
If you are not familiar with the DMX standard, or if you need information about the DMX
cables needed to link the Ilumipod Inground Tri-12 IP Optic WW to a DMX controller, you
may download the “DMX Primer” from the ILUMINARC® website at

http://www.iluminarc.com/reports/dmx-primer

.

DMX Modes

The Ilumipod Inground Tri-12 IP Optic WW uses the standard DMX data connection for its
SOLID personality. Refer to the

Introduction

chapter for a brief description of this mode.

Refer to the

Operation

chapter to learn how to configure the Ilumipod Inground Tri-12 IP

Optic WW to work in this mode. The

DMX Values

section provides detailed information

regarding the DMX mode.

DMX Mode

DMX Address

SOLID

512

Signal Wiring

To provide signal for the Ilumipod Inground Tri-12 IP Optic WW, you can connect the bare-
ended, IP67-rated signal cable from the product to two IP67-rated signal connectors
(DMX In/DMX Out) or use an IP67-rated junction box and IP67-rated conduit.

Protocol Connectivity

The Ilumipod Inground Tri-12 IP Optic WW uses the USITT DMX 512 Protocol. The
procedure below illustrates the recommended connection method.


























Advertising