3. INSTALLATION

Operation manual b42, chapter 3 -installation- page 3-3

Electrical specification:

GPI input

potential free by opto-coupler, low active

OFF:

+3.5…+30V between GPI input

and

pin14

ON:

less then 1.5V

Min

50ms


Note: If using an external voltage feed it has to be connected to pin 14!
External Ground is switching the GPI on any of the inputs.
An internal voltage feed is available on pin 15. Ground is available from the
shield of the connector only! By using the internal voltage feed there is no
electrical isolation given anymore.










The digital dynamics processor b42 can transmit specific device
statuses via parallel Tally lines.

use:

Control of the remote-controlled changeover of
presets

connector:

D-SUB 15pin, male

3.7.2

TALLY OUT

min. 50 ms

+1,5V

+3,5...30V

Pin1...13

Ext. voltage
feed+3,5...30V

Pin14

Contact to
ext. Ground