NEXCOM VTC 6200 User Manual

Page 18

Advertising
background image

Copyright © 2011 NEXCOM International Co., Ltd. All rights reserved

5

VTC 6200 / VTC 6200-NI / VTC 6200-NI-DK User Manual

Chapter 1: Product Introduction

Power Management
• Power-on delay time is selectable by BIOS to disable and enable in 10sec

/ 30sec / 1min / 5min / 10 min / 15min / 30min / 1hr.

• Power-off delay time is selectable by BIOS to disable and enable in 20sec

/ 1min / 5min / 10min / 30min / 1hr / 6hr / 18hr.

• S3, S4 suspend mode
• Ignition On/Off status detectable by SW
• Low battery status detectable by SW
• Ignition enable/disable is jumper selectable
• Shut down system automatically when the system’s internal temperature

is over 80C.

• VTC 6200 / VTC 6200-NI / VTC 6200-NI-DK will automatically shut

down 5 minutes after the duration of low battery voltage is over 60 sec.
User can detect this situation via software.

• If the ignition is off and the system is still on after 3 minutes, VTC 6200 /

VTC 6200-NI / VTC 6200-NI-DK will shut down automatically.

• If the ignition is off, the user can detect this status via the software.
• If the ignition is turned on again and the power-off delay is in progress,

VTC 6200 / VTC 6200-NI / VTC 6200-NI-DK will cancel the delay
function and will continue to operate normally.

• If the ignition is turned on again and the power-off delay ended, VTC

6200 / VTC 6200-NI / VTC 6200-NI-DK will shut down completely will
power-on again automatically.

• If the ignition is turned off again and power-on delay is in progress, VTC

6200 / VTC 6200-NI / VTC 6200-NI-DK will cancel the delay and stay in
power-off status.

• If the ignition is turned off again and the power-on delay ended

(entered OS already), VTC 6200 / VTC 6200-NI / VTC 6200-NI-DK will
continue to operate normally.

• If the ignition is turned off again and the power-on delay ended (in BIOS

process), VTC 6200 / VTC 6200-NI / VTC 6200-NI-DK will shut down
immediately.

• If VTC 6200 / VTC 6200-NI / VTC 6200-NI-DK is off, only below 10mA is

used.

Advertising
This manual is related to the following products: