Spot-1, Specifications – Oxmoor SPOT-1 User Manual

Page 2

Advertising
background image

Oxmoor Corporation, LLC, 309 Cahaba Valley Parkway, Birmingham, AL 35124 USA Toll Free: 1-800-262-6898

Phone: 205-982-8200 Fax: 205-982-8250 E-mail: [email protected] Internet: www.oxmoor.com

10' On Center

10' On Center

Receiver 4' Off Floor

Optimum Coverage Area

8' Ceiling

SPOT-1

SPECIFICATIONS

Specifications subject to change without notice.

Rev. 7/01

INPUT TYPE

INPUT TYPE

INPUT TYPE

INPUT TYPE

INPUT TYPE ................................................................................................

................................................................................................

................................................................................................

................................................................................................

................................................................................................ RF

INPUT CONNECTOR

INPUT CONNECTOR

INPUT CONNECTOR

INPUT CONNECTOR

INPUT CONNECTOR ....................................................................................

....................................................................................

....................................................................................

....................................................................................

.................................................................................... BNC

INPUT IMPEDANCE

INPUT IMPEDANCE

INPUT IMPEDANCE

INPUT IMPEDANCE

INPUT IMPEDANCE ..................................................................................... 25 k ohms at 95 kHz

MAXIMUM CARRIER FREQUENCY

MAXIMUM CARRIER FREQUENCY

MAXIMUM CARRIER FREQUENCY

MAXIMUM CARRIER FREQUENCY

MAXIMUM CARRIER FREQUENCY ................................................................

................................................................

................................................................

................................................................

................................................................ 3 mHz

MAXIMUM RF INPUT LEVEL WITH 50 OHM LINE TERMINATION

MAXIMUM RF INPUT LEVEL WITH 50 OHM LINE TERMINATION

MAXIMUM RF INPUT LEVEL WITH 50 OHM LINE TERMINATION

MAXIMUM RF INPUT LEVEL WITH 50 OHM LINE TERMINATION

MAXIMUM RF INPUT LEVEL WITH 50 OHM LINE TERMINATION ..................

..................

..................

..................

.................. 3 Vpp (13.5 dBm)

NUMBER OF DIODES

NUMBER OF DIODES

NUMBER OF DIODES

NUMBER OF DIODES

NUMBER OF DIODES ..................................................................................

..................................................................................

..................................................................................

..................................................................................

.................................................................................. 72

IR OUTPUT

IR OUTPUT

IR OUTPUT

IR OUTPUT

IR OUTPUT .................................................................................................. 1.5 W / Steradium, On Axis

WAVE LENGTH OF RADIATED INFRARED LIGHT

WAVE LENGTH OF RADIATED INFRARED LIGHT

WAVE LENGTH OF RADIATED INFRARED LIGHT

WAVE LENGTH OF RADIATED INFRARED LIGHT

WAVE LENGTH OF RADIATED INFRARED LIGHT ...........................................

...........................................

...........................................

...........................................

........................................... 880 nm

AUTOMATIC ON/OFF FUNCTION, INTERNAL JUMPER SELECT

AUTOMATIC ON/OFF FUNCTION, INTERNAL JUMPER SELECT

AUTOMATIC ON/OFF FUNCTION, INTERNAL JUMPER SELECT

AUTOMATIC ON/OFF FUNCTION, INTERNAL JUMPER SELECT

AUTOMATIC ON/OFF FUNCTION, INTERNAL JUMPER SELECT ....................

....................

....................

....................

.................... Carrier Detect for 95 kHz and 250 kHz

SAFETY LISTING

SAFETY LISTING

SAFETY LISTING

SAFETY LISTING

SAFETY LISTING ..........................................................................................

..........................................................................................

..........................................................................................

..........................................................................................

.......................................................................................... UL & Plenum

STORAGE TEMPERATURE

STORAGE TEMPERATURE

STORAGE TEMPERATURE

STORAGE TEMPERATURE

STORAGE TEMPERATURE ............................................................................

............................................................................

............................................................................

............................................................................

............................................................................ 0

°

C to 70

°

C

OPERATING TEMPERATURE

OPERATING TEMPERATURE

OPERATING TEMPERATURE

OPERATING TEMPERATURE

OPERATING TEMPERATURE ........................................................................

........................................................................

........................................................................

........................................................................

........................................................................ 10

°

C to 50

°

C

HUMIDITY

HUMIDITY

HUMIDITY

HUMIDITY

HUMIDITY ...................................................................................................

...................................................................................................

...................................................................................................

...................................................................................................

................................................................................................... 80% Max., Non-condensing

AC POWER

AC POWER

AC POWER

AC POWER

AC POWER .................................................................................................. 90-264 VAC, 35 Watts, 47 to 63 Hz

PACKAGING

PACKAGING

PACKAGING

PACKAGING

PACKAGING ................................................................................................

................................................................................................

................................................................................................

................................................................................................

................................................................................................ Recessed 6-in. H7TH-Type Housing

MOUNTING

MOUNTING

MOUNTING

MOUNTING

MOUNTING .................................................................................................

.................................................................................................

.................................................................................................

.................................................................................................

................................................................................................. Ceiling Mount

DIMENSIONS

DIMENSIONS

DIMENSIONS

DIMENSIONS

DIMENSIONS ...............................................................................................

...............................................................................................

...............................................................................................

...............................................................................................

............................................................................................... 203mm H x 279mm W x 356mm D

(8 in. H x 11 in. W x 14 in. D)

WEIGHT

WEIGHT

WEIGHT

WEIGHT

WEIGHT ......................................................................................................

......................................................................................................

......................................................................................................

......................................................................................................

...................................................................................................... 2.4kg (5 lb. 3 oz.)

COVERAGE FOR CEILING INSTALLATION HEIGHT:

COVERAGE FOR CEILING INSTALLATION HEIGHT:

COVERAGE FOR CEILING INSTALLATION HEIGHT:

COVERAGE FOR CEILING INSTALLATION HEIGHT:

COVERAGE FOR CEILING INSTALLATION HEIGHT:

Single Channel with a Ceiling Height of .............................................. 24 ft.
Optimum Radius 4 ft. from the Floor Surface ..................................... 30 ft.
Maximum Radius 4 ft. from the Floor Surface ..................................... 45 ft.

Single Channel with a Ceiling Height of .............................................. 12 ft.
Optimum Radius 4 ft. from the Floor Surface ..................................... 20 ft.
Maximum Radius 4 ft. from the Floor Surface ..................................... 35 ft.

Single Channel with a Ceiling Height of ................................................ 9 ft.
Optimum Radius 4 ft. from the Floor Surface ..................................... 16 ft.
Maximum Radius 4 ft. from the Floor Surface ..................................... 30 ft.

Single Channel with a Ceiling Height of ............................................... 8 ft.
Optimum Radius 4 ft. from the Floor Surface ..................................... 10 ft.
Maximum Radius 4 ft. from the Floor Surface ..................................... 20 ft.

Side View Of Typical Ceiling Installation With Ceiling Height of 8 Feet

Advertising