3. Introduction

The RCD-1 family of paging data receivers are high performance receiver modules which are ideal for
remote control, one-way telemetry, and wide-area wireless messaging. They feature:

1 relay output port, configurable as automatically or command code controlled

Uses POCSAG or FLEX digital paging formats, depending upon factory configuration

Receives 512, 1200, or 2400 baud POCSAG (applies only to POCSAG Model)

Synthesized receiver - No crystals required

RS-232 port for data output

Compact size

Activity and Power LED

Receives alpha or numeric messages

External antenna

Timed or static digital output when relay output is used

Positive lock connectors

Wall mountable case

Directly compatible with Adaptive™ LED message boards

Responds to industry standard “7xxx” output control commands when configured for relay
control mode

WaveWare’s RCD-1 paging data receivers allow a user to remotely control electrical devices over very
wide areas, even nation-wide! Because they use industry standard paging protocols, an RCD-1
communication system may be as small or as large as one wishes. A user may utilize their own on-site
transmitter or they may utilize a paging carrier’s wide-area network.

The RCD-1 receivers decode paging signals, and provide an RS-232 output of the received message. If the
RCD-1 is configured for remote control, and a message is formatted in the common “7xxx” output control
format, the digital output relay will respond appropriately. The digital output may be used to control relays,
external loads, or a host of other electro-mechanical devices. A built-in timer allows the outputs to be
turned on for specific amounts of time, after which they are automatically turned off. This is particularly
useful for lighting and pump control.