Troubleshooting, Overview, Cannot download code – Zilog EZ80F91 User Manual

Page 61: Irda port not working

Advertising
background image

eZ80F91 Development Kit

User Manual

UM014220-0508

Troubleshooting

56

Troubleshooting

Overview

Before contacting Zilog Customer Support to submit a problem report,
follow these simple steps. If a hardware failure is suspected, contact a
local Zilog representative for assistance.

Cannot Download Code

If you are unable to download code to RAM using ZDS, ensure to press
and release the Reset button on the eZ80Acclaim!

®

Development Kit

prior to selecting Debug

Reset and then Debug

Go in ZDS II.

IrDA Port Not Working

If you plan to use the IrDA transceiver on the eZ80F91 Module, ensure
that the hardware is set up as follows:

Jumper J2 must be OFF (to enable the control gate that drives the
IrDA device).

Set port pin PD2 Low. When this port pin and Jumper J2 are turned
OFF, the IrDA device is enabled.

Install a jumper on connector J6 across pin names con_dis and GND
to disable the console serial port driver.