Location requirements, Warning: shock hazard – AMETEK XG 850 Watt Series Rack-Mount User Manual
Page 3
XG 850 Watt Rack Mount Kit Options
M370078-05
3
Location Requirements
Install the XG in a location that meets the following requirements:
Condition
Description
Clean
The XG should not be exposed to metal filings or any other form of conductive contamination.
Cool
The ambient air temperature should be between 0 °C–50 °C (32 °F–122 °F) for best performance.
Ventilated
Whether operating the power supply in a rack or on a bench, allow air to reach the ventilation
inlets on the front and rear of the unit for cooling. The direction of airflow is from the front to the
back of the unit. Ventilation space at the top, bottom or sides of the power supply is not required
WARNING: Shock hazard
Ensure that any mounting screws do not penetrate more than 1/8 in. (3.0 mm) into the bottom
and/or the back of the unit.