Group

Name

Cmd RespDescription

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

Index #3

IN_KEYING_INVERT

KI

KI Invert keying area

Rd/Wr 0

1

0

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

IN_KEYING_GRAB_ENABLE

Kg

Kg

Enable/disable the keying color
grabber mode

Rd/Wr 0

1

0

0 = Disable the grabber
1 = Enable the grabber

IN_KEYING_GRAB_GET

Kc

Kc

Capture the coolor selected by the
grabber and apply the settings

Rd/Wr 0

1

0

Percent of
OSCREEN_UTIL_H

IN_KEYING_GRAB_H

Kh

Kh Horizontal position of the grabber

Rd/Wr 0

65535 32768

Precent of
OSCREEN_UTIL_V

IN_KEYING_GRAB_V

Kv

Kv Vertical position of the grabber

Rd/Wr 0

65535 32768 Auto reset

INPUT
STATUS

SIG_HPOL

sh

sh Input H sync polarity

Rd

0

1

0

0 = Negative Synchro
1 = Positive Synchro

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

SIG_VPOL

sv

sv Input V sync polarity

Rd

0

1

0

0 = Negative Synchro
1 = Positive Synchro

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14