Group

Name

Cmd RespDescription

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

Index #3

SET_FREEZE

Sf

Sf Freeze of the input

Rd/Wr 0

1

0

1 = Freeze

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

SET_MOTION_DETECT

Sm Sm

0 : max correction; 15 : min
correction

Rd/Wr 0

15

15

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

PRESET
ELEMENT

PE_INPUTNUM

IN

IN

Displayed input number or frame or
logo number

Rd/Wr 0

14

0

0 = No input
1 = Input1
2 = Input2
3 = Input3
4 = Input4
5 = Input5
6 = Input6
9 = Input9
10 = Input10
11 = Input11
12 = Input12
13 = Input13
14 = Input14

0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory Preset
1
4 = Memory Preset
2
5 = Memory Preset
3
6 = Memory Preset
4
7 = Memory Preset
5
8 = Memory Preset
6
9 = Memory Preset
7
10 = Memory
Preset 8

0 =
Background
Frame
2 =
Background
Layer
3 = Pip 1
Layer

6 = Logo 1
8 = Audio
Output 1
9 = Audio
Output 2

Advertising