DLC274M Front Panel LEDs

LED

Function

Color

Description

OK

DLC274M

Module

Status

OFF

If power is applied to the system, an internal fault with the DLC274M may exist

n

Green

Normal operation

n

Yellow

If no other status LEDs indicate a minor alarm, then a temperature alarm is indicated

n

Red

If no other status LEDs indicate a major alarm, then an internal error is indicated, such

as an onboard communications error or an onboard power error

EMS

DigiLink Manager

System

Status

OFF

The DLC274M module is in local mode and its configuration is controlled by the

onboard configuration switches

n

Green

The DLC274M module is in remote mode and the configuration has been set by

DigiLink Manager. When in remote mode, the actual configuration of the module

will likely not match the settings of the configuration switches and changing the

configuration switches will have no effect on the module operation

TX

Transmitter

Status

OFF

Transmitter is disabled

n

Green

Normal operation

n

Red

SFP TX failure exists

Red

No SFP is installed

RX

Receiver

Status

OFF

Receiver is disabled

n

Green

Receiving a 270 Mb/s signal

n

Yellow

Standby signal is being received

Yellow

Receive optical power is high

n

Red

Incorrect input signal type (for example, not a 270 Mb/s signal)

Red

Possible causes:

No SFP is installed (RX and TX LEDs are both flashing)

A low receiver power condition exists

An SFP RX failure exists

A, B,

C, D

270 Mb/s

Channel

Status

OFF

Input disabled

n

Green

270 Mb/s video detected

n

Yellow

No signal applied

n

Red

Video input signal rate is outside the range (270 Mb +/- 100 ppm)

Flashing yellow |

Flashing red

Install SFP

AR208-008020-B00_D

270 Mb/s Digital Video 4-to-1 TDM Multiplexer with

Optical Transmitter/Receiver/Repeater [DLC274M]