Hardware preparation and installation, 1 environmental and power requirements, 1 environmental requirements – Artesyn COMX-P4080 Installation and Use (August 2014) User Manual

Page 35: Table 2-1, Environmental requirements, Outline, Chapter 2

Advertising
background image

Chapter 2

COMX-P4080 COM Express Module Installation and Use (6806800L20C)

35

Hardware Preparation and Installation

2.1

Environmental and Power Requirements

2.1.1

Environmental Requirements

The following table lists the environmental requirements that the board must meet when
operated in your particular system configuration.

Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.

Product Damage:

High humidity and condensation on surfaces cause short circuits.

Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying
power.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Cooling Method

Forced-air

Temp Cycle Class

-40 to +85 °C:500cyc

Temperature

0 to 55 °C

-40 to 85 °C

Humidity

10-90% (non-condensing)

Vibration

0.01g^2/Hz @ 5-500 Hz

Shock

20 g 11 ms sine or saw

Altitude

-60 to 4000 m ASL

Advertising