Maintenance, Yearly maintenance (or every two tons), Clean the vertical exhaust duct – Avalon Firestyles Astoria 2001 to 2002 User Manual

Page 32: Clean the exhaust duct

Advertising
background image

3 0

Maintenance

Travis Industries

4 0 1 1 0 0 9

9 3 5 0 8 1 2 6

Yearly Maintenance (or every two tons)

WARNING:

Disconnect the power cord prior to conducting service.

The following section details extensive maintenance procedures. We strongly suggest these items
be carried out by a trained service technician, possibly by a service agreement set up with your dealer.

Soot and Flyash: Formation and Need for Removal – The products of combustion will
contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the
flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect
operation of the room heater will lead to some soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected at least once every year to determine if
cleaning is necessary.

Clean the Vertical Exhaust Duct

(the stove must be cool and unplugged)

Clean the refractory and

the entire area behind it

(both sides).

Remove these doors to

remove fallen flyash and

soot (see “Bi-Weekly

M i t

f

d t il ”)

Remove both

refractory clips.

Clean the Exhaust Duct

(the stove must be cool and
unplugged)

Remove the
cover plates over
the exhaust duct
(both sides)

b

Swing the side panels open.

7/16" Nutdriver

c

Cover Plate

Use a vacuum or
bottle brush to
remove all flyash
from the exhaust
duct.

Phillips

Screwdriver

Open the hopper lid and remove the two
screws holding the side doors in place.

d

a