Zc kit – agp pellet insert, Minimum floor protection – Avalon Firestyles AGP Pellet Insert User Manual

Page 5

Advertising
background image

ZC Kit – AGP Pellet Insert

(94400157)

Page 5 of 10

17601823 - 3/7/14

© Travis Industries, Inc.

Minimum Floor Protection

 The insert must be placed on the bottom panel (shipped with the kit).
 The area directly under the insert in front of the bottom panel (10” by 24.75”) must have an R value of 1.0

or greater.

Hearth pads are available with R value protection. Manufacturers of these pads are listed below:

- Hearth Classics - - Grayson Wood -

 Additional floor protection must extend 6” in front of the door opening (16” from the enclosure opening)

and the full width of the surround panel (42” min. width). This floor protection must be non-combustible
(no minimum R value – it is used as spark protection).

42" Min.

(width of surround panels)

16" Min.

Bottom Panel

(included with kit)

Floor Protection

This area directly underneath the insert

must have an R value of 1.0 or greater.

The remaining floor protection must be

non-combustible (spark protection).

10"

24.75"

RAISED HEARTH EXAMPLES

The illustrations below detail two typical hearth installations.

1" Floor Protection

1" Thick Floor Protection

Bottom Panel (1/2" Thick)

Use the leveling

bolt on the insert to

adjust the height at

the rear.

Sub-Floor

3.5" Floor Protection

3.5" Thick Floor
Protection (Brick)

Bottom Panel (1/2" Thick)

For thick facing you

may wish to build a

platform under the

bottom panel.

Sub-Floor