4

O

PERATION

4.1 A

CTIVATION

AND

SHUT

-

DOWN

ALS

350
450

Start dispensing labels

– The conveyor belt starts up. The first product reach-

es the product sensor (photoelectric sensor) [43].

– The product sensor sends a start signal.
– The start signal from the product sensor triggers the

dispensing of a label (label feed) using the set val-
ues for dispensing speed, label distance, etc.

– The dispensing of labels automatically runs in the

same manner for the following products.

[43] The product sensor (A) has detected a product (B) at the dis-

pensing edge and sends a start signal.

B