Aviosys 8870 User Manual

Page 4

Advertising
background image

4

SDK

For user to arrange own development :

 Developing environment: :

VB.NET 2008 , Microsoft NET. Framework Version 3.5 , Microsoft office access 2007

USB CDC series emulation model .

USB e-Meter 8870 support USB CDC emulation model , Please refer the following :

1. First , make sure that the 8870 is connect with your PC. Please go to

Control Panel  System  Device manager  Ports(COM& LPT)  Aviosys Port (COM X)

2. Then open Hyper terminal to connect with 8870.

Start  All programs Accessories  Communication  Hyper terminal

* There is no Hyper terminal program in WIN 7. Please use other serial software like Putty .

Select the COM port 8870 use .

3. Setup

“ Bits per second” as 19200 and “ Flow control” as NONE. Then press OK to log in .

RS232:

 Read Device model : Command is ~

 Read current : Command is @

Thank you for support Aviosys .

If any question please email to our Service Dep. : [email protected].