Fuse Protection

A blown fuse in the VK-P6SE may be an indication of a serious problem. If a

replacement fuse fails as well, no further attempts should be undertaken.

Please contact the factory for professional service.

The proper fuse ratings are as follows:

For 100-120 VAC Units:

2A 250V Slow Blow

For 200-240 VAC Units:

1.5A 250V Slow Blow


WARNING:

Factory supplied fuses should be only replaced with the same type

and rating parts.


Servicing

The Balanced Audio Technology VK-P6SE should require no service other than

changing tubes to maintain its high performance. The vacuum tubes used in

the VK-P6SE are high quality 6922’s and 6SN7’s rated for approximately

5000 hours of use. Please direct any further service inquiries to the factory.

Cleaning

To remove dust, occasionally wipe the front and top surfaces of your VK-P6SE

with a damp soft cloth. If fingerprints appear, you may use a mild, non-

alkaline soap solution. Do not use abrasive cleaners, as they may damage the

fine finish of the unit.