Maintenance and cleaning, What if there are problems, 1 cleaning the device – Beurer IPL 7000 User Manual

Page 37: 2 replacing the cartridge

Advertising
background image

37

7. Maintenance and cleaning

7.1 Cleaning the device

After each hair removal session it is recommended that you clean your device, paying par-

ticular attention to the light area.

When cleaning, do not use any solvents or other aggressive or abrasive cleaning

agents, as the surface may become damaged.

Never immerse the device or any of its parts in water!

1. Before cleaning, remove the mains adapter of the device from the socket.

2. Clean the housing of the device with a dry, clean cloth.

3. Gently clean the light area and skin contact sensor using a slightly

damp, lint-free cloth.

7.2 Replacing the cartridge

The cartridge has a life cycle of up to 100,000 light pulses, which is sufficient for up to

26 years for normal use (one user, full body treatment including legs, arms, armpits, bikini

zone and face). This means that the cartridge for this model does not usually need to be

replaced.

If the indicator lamp flashes red, the lamp has reached 90% of its service life.

Note

The cartridge should only be replaced if there are large spots visible or if the lens is broken.

If this is the case, please contact beurer Customer Services.

8. What if there are problems?

“The device will not switch on”

• Ensure that the mains cable is correctly connected to the device.

• Ensure that the mains adapter is inserted into a wall socket.

“No light pulse is emitted when I press the trigger button”

• Ensure that the device is in full contact with the skin and that the light area and skin con-

tact sensor are pressed onto the skin evenly and firmly. For your safety, the trigger but-

ton only activates a pulse if the skin contact sensor is completely covered by the skin.

• If the indicator lamp on the device is illuminated red, this indicates that your skin colour,

as measured by the skin colour sensor, is too dark for safe application. Test the device

on another part of your body or contact Customer Services.

Advertising