18

PROBLEM CAUSE REMEDY

Does not run No power to Check power line supply voltage.

indicator light off. machine. Plug in line cord firmly.

Does not run, Wiring shorts. Disconnect machine and indicator

light off.

examine internally; rewire at fault.

‘ Circuit breaker

tripped.

If none found, throw direction

switch to ‘OFF”, reset breaker

and plug in.

Shorted motor. If breaker does not trip, replace

drive unit.

Faulty speed If breaker trips again, replace

control board. control board.

(OR)

Burned out

transformer. Replace transformer.

Does not run, Bad connection. Check wiring connections,

indicator light on.

12 VAC should appear

across secondary of transformer.

Tighten terminal screws on speed

control board.

Faulty speed If DC Volts = 0 across leads to

control board. motor; replace control board.

Unit runs,

Faulty speed Replace control board.

but no control control board. (Check connection first).

over speed.

NOTE: Make sure unit is plugged into correct voltage,

(120VAC, 240VAC, 42VAC) corresponding to Model No.rating.

12 VAC should appear across secondary of transformer in all DC III Drive Units.

TROUBLESHOOTING GUIDE