12 ......... electrical component chart, Wiring diagram / bug-5100-f dc iii drive unit, Vacuum support kit – BUG-O Systems CIR-O User Manual

Page 12: Electrical component chart

Advertising
background image

12

WIRING DIAGRAM / BUG-5100-F DC III
DRIVE UNIT

120 (42) VAC
INPUT

240 VAC
INPUT

CB

BLK

BLK

WHT

A

D

V

WHT

T

TAN
TAN

RED

12 VAC

YEL

DK. BLU

DK. BLU

WHT/BLU

P

1
2
3
4
5
6
7
8

POT

M-

M+

AC

F

S

M

PK

GY

RED

BLK

CB

BLK

A

WHT

D

BLK

T

12 VAC

ELECTRICAL COMPONENT CHART

ITEM DESCRIPTION

BUG-5100-F

BUG-5102-F

BUG-5104-F

120 VAC

240 VAC

42 VAC

A

Power Cord

BUG-9445

GOF-3115

BUG-9442

CB

Circuit Breaker

BUG-2923 (.7A)

BUG-2952 (.5A)

BUG-2933 (2A)

D

Pilot Light

BUG-1415

BUG-1428

BUG-1427

V

Volt Trap

BUG-1393

BUG-1563

BUG-1393

T

Transformer

BUG-9675

GOF-3112

BUG-1466

M

Gear Motor

* BUG-1550 (150:1)

F

Precision Speed Control

BUG-1725

S

Toggle Switch

BUG-2255

P

Potentiometer Control

BUG-9686

* BUG-1600 (50:1)

BUG-1595 (100:1)

PART NUMBER

13

CON-1006 VACUUM SUPPORT KIT can be mounted on any CIR-0 or CON-0
ring base with standard CON-1003 legs. Vacuum pump kits are available for
operation on 120 VAC [ARV-2020] or 240 VAC [ARV-2030]

Each vacuum cup holds 50 lbs (22 kg).

(Dirt and scale block vacuum lines; blow-out when clogged).

Keep flame 4'' (100 mm) away from cups when burning or welding. Silicone
vacuum cups will withstand a temperature of 600°F (318° C).

ITEM PART NO.

DESCRIPTION

1 ARV-1004-14

Hose 14" (355 mm)

2 ARV-1005

Hose Clamp

3 ARV-1013

Male Quick Connector 1/4 NPT

4 ARV-2020

Vacuum Pump Kit (I 20 VAC/60 Hz/1 Ph)

ARV-2030

Vacuum Pump Kit (220 VAC/60 Hz/1 Ph)

5 ARV-1034

Choke Nipple

6 ARV-1107

3/8'' Hose Barb 1/4 NPT

7 ARV-1109

Protective Cap

8 ARV-1116

Vacuum Cup (Silicone) 50 lbs. (22 kg)

9 CON-1007

Vacuum Leg

10 CON-1020

Double Swivel Clamp Assembly

Vacuum Pump is not included in CON-1006 Vacuum Support Kit.

VACUUM SUPPORT KIT

10 1 2

9 6

7
8 4

5

3

Advertising