21 ........troubleshooting guide, Troubleshooting guide – BUG-O Systems GO-FER III-OX User Manual

Page 21

Advertising
background image

21

PROBLEM

CAUSE

REMEDY

Does not run,

No power to

Check power line supply voltage.

indicator light off.

machine.

Plug in line cord firmly.

Does not run,

Wiring shorts.

Disconnect machine and

indicator light off.

examine internally;

rewire at fault.

Circuit breaker

tripped.

If none found, throw direction

switch to “OFF”, reset breaker

and plug in:

Shorted motor.

If breaker does not trip, replace

drive unit.

Faulty speed

If breaker trips again, replace

control board.

control board.

(OR)

Burned out

transformer.

Replace transformer.

Does not run,

Bad connection.

Check wiring connections,

indicator light on.

12 VAC should appear

across secondary of transformer.

Tighten terminal screws on

speed control board.

Faulty speed

If DC Volts = 0 across leads to

control board.

motor; replace control board.

Unit runs,

Faulty speed

Replace control board.

but no control

control board.

(Check connection first).

over speed.

NOTE: Make sure unit is plugged into correct voltage,

(120 VAC, 240 VAC, 42 VAC) corresponding to Model No. rating.

12 VAC should appear across secondary of transformer in all

GO-FER III Drive Units.