Operating instructions 7 operating instructions – Campomatic AC12MP User Manual

Page 9

Advertising
background image

OPERATING INSTRUCTIONS

7

Operating Instructions

- Press the "MODE" button until the "COOL"
indicator light comes on.
- Press the ADJUST buttons "▲" or " " to
select your desired room temperature. The
temperature can be set within a range of

O

O

O

O

17 C-30 C/62 F-86 F.
- Press the "FAN SPEED" button to choose the
fan speed.

- Press the "MODE" button until the
"DRY" indicator light comes on.

COOL operation

DRY operation

- Press the "MODE" button until the
"FAN " indicator light comes on.
- Press the "FAN SPEED" button to
choose the fan speed. The temperature
cannot be adjusted.
- Do not put the duct to window.

FAN operation

TIMER operation

- Press the "MODE" button until the "HEAT"
indicator light comes on.
- Press the ADJUST buttons "▲" or " " to
select your desired room temperature. The
temperature can be set within a range of

O

O

O

O

17 C-30 C/62 F-86 F.
- Press the "FAN SPEED" button to choose the
fan speed. For some models, the fan speed
can not be adjusted under HEAT mode.

HEAT operation

(cooling only models without)

AUTO operation

- When you set the air conditioner in
AUTO mode, it will automatically select
cooling, heating(cooling only models
without), or fan only operation depen-
ding on what temperature you have
selected and the room temperature.

- When the unit is on, first press the
Timer button, the TIMER OFF
indicator light illuminates. It indi-
cates the Auto Stop program is
initiated.
- When the unit is off, first press the
Timer button, the TIMER ON indic-
ator light illuminates. It indicates
the Auto Start program is initiated.
- Press or hold the UP or DOWN
button to change the Auto time by
0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24
hours. The control will count down
the time remaining until start.
- The selected time will register in 5
seconds and the system will autom-
atically revert back to display the
previous temperature setting.
- Turning the unit ON or OFF at any
time or adjusting the timer setting
to 0.0 will cancel the Auto Start/
Stop timed program.
- When the malfunction (E1 or E2)
occurs, the Auto Start/Stop timed
program will also be cancelled.

- The air conditioner will control room
temperature automatically round the
temperature point set by you.
- Under AUTO mode, you can not
select the fan speed.

Press and hold the SWING and MODE
buttons simultanuously for 3 seconds,
the auto sliding panel will be locked .
Press and hold the two buttons simultanuouly
for 3 seconds to cancel the lock function.

- Under this mode, you cannot select a
fan speed or adjust the temperature.
- Keep windows and doors closed for
the best dehumidifying effect.
- Do not put the duct to window.

E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E5- The auto sliding panel malfunction-
Unplug the unit and plug it back in.
If error repeats, call for service.
P1- Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.
E0- Unit malfunction-- Unplug the unit and plug
it back in. If error repeats, call for service.

11

LOCK function

9

INDICATOR LIGHTS display

- lights up when the POWER is on.

- lights up when LOCK function is set.

- lights up when TIMER ON function is set.
- lights up when TIMER OFF function is set.
- lights up when FOLLOW ME function is set.
- lights up when SLEEP function is set.

- lights up when FRESH function is set by
remote controller.

Error codes:
E1-
Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.

Advertising