Humidity sensor

In the movement process,this device is used for induction clothing humidity,it means
that it must be carried on cleaning.Major cause of clean is must scour out the calcium
oxide boiler which on the sensor surface up.Clean the sensor in the tumble(See picture).

Lamp replace (option)

1.Open the door,put your hand into the drum of the dryer,use screw driver unscrew
two pieces of screw,and take out the lamp cover.

2.Remove the lamp by turning counter clockwise.Be carefully,do not let the lamp fall off.
Then install the new lamp and lamp cover with the reverse direction.

Condenser is one of the very important assembly to realize effective drying,therefore need
special attenton.Suggest you clean the condenser three or four times every year.
(Notice:when the condenser is not assembled in proper position,the alarm will ring).

1.Open condenser cover

2.Move two pieces of lock rod,pull out the condenser

3.Put the condenser under the tap to make water through completely by clean condenser.

4.Install the condenser with the reverse direction.