Ò³ãæ 15, Specifications – Campomatic Window AC User Manual

Page 15

Advertising
background image

Solution

Problem

Air conditioner turns on
and off rapidly

Noise when unit is
cooling

Water dripping
INSIDE when
unit is cooling.

Improper installation. Tilt air conditioner slightly to the outside to
allow water drainage. Refer to installation instructions - check with
installer.

Dirty air filter- air restricted. Clean air filter.

Air movement sound. This is normal . If too loud, turn selector to
lower FAN setting.

Outside temperature extremely hot. Set to high cool to bring air
past cooling coils more frequently.

Sound of fan hitting water-moisture removal system. This is normal
when humidity is high. Close doors, windows and registers.

Window vibration - poor installation. Refer to installation instructions
or check with installer.

Water dripping
OUTSIDE when
unit is cooling.

Unit removing large quantity of moisture from humid room. This is
normal during excessively humid days.

Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section.

Unit recently turned on in hot room. Allow additional time to remove Stored heat from
walls, ceiling, floor and furniture.

Air conditioner
cooling, but room
is too warm- NO
ice forming on
cooling coil behind
decorative front.

Thermostat set too warm. Turn thermostat clockwise to a colder setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution.
Clear blockage in front of unit.

Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers.

SPECIFICATIONS

12

Unit dimensions:

MODEL
(Btu/h)

BODY DIMENSION(mm)
(W X H X D)

5000~6000

445X320X415

450X346X535

15000~16000

560X400X640

660X434X620

660X428X680

15000~24000

660X428X780

7000~9000

450X346X535

9000~12000

600X380X560

NOTE: Value of D is for reference only.