1 - Electrical Installation

6

CONNECTING FEEDER
CABLE

To connect the feeder cable to the
cooker it is necessary to:

– Remove the screw that hold shield

A” behind the cooker (fig. 1.1).

– Insert the feeder cable of the suitable

section (as described in the next
chapter) into the cable clamp “D”.

– Connect the phase and earth cables

to the terminal block “B” according to
the diagram in figure 1.2.

– Pull the feeder cable and block it with

cable clamp “D”.

– Re-mount shield “A”.

The appliance must be connected to the electrical network verifying above all that the
voltage corresponds to the value indicated on the specifications plate and that the
cables section of the electrical plant can bear the load which is also indicated on the
plate.

It is recomended that the appliance is connected directly to the mains by fixed wiring,
placing a double pole switch with minimum opening between the contacts of 3 mm.
Alternative connection methods may be available as long as they conform to current
IEE wiring regulation.

The power supply cable must not touch the hot parts and must be positioned so that
it does not exceed 75°C at any point.

Once the cooker has been installed, the switch must always be accessible.

Before effecting any intervention on the electrical parts the appliance must be
disconnected from the network.

Warning!
Electricity can be extremely dangerous.
This appliance must be earthed.

Feeder cable section

type H05RR-F

230 V

3 x 1,5 mm

2

D

B

A

PE

Fig. 1.1

230 V

PE

N

L

1

(L

2

)

Fig. 1.2

Advertising