1 - electrical installation - wall box connection, Connecting feeder cable – Caple CR9205 User Manual

Page 7

Advertising
background image

7

1 - Electrical Installation - Wall box connection

This appliance must be connected to a
double pole isolating switch (fig. 1.1) and
to the terminal block in the cooker (figs.
1.2 & 1.3) using the following guide:

FUSE

DOUBLE POLE SWITCHED

FUSED SPUR OUTLET

USE A 20 AMP FUSE

ON

Fig. 1.1

1) The wire which is coloured brown

must be connected to the terminal
marked L (Live), or coloured Red.

2) The wire which is coloured blue must

be connected to the terminal marked
N (Neutral), or coloured Black.

3) The wire which is coloured green and

yellow must be connected to the ter-
minal marked E (Earth)

or

coloured Green.

IMPORTANT: These connections must
be carried out by a qualified electrical
engineer.

CONNECTING FEEDER CABLE

To connect the feeder cable to the cook-
er it is necessary to:

– Remove the screw that hold shield “A

behind the cooker (fig. 1.2).

– Insert the feeder cable of the suitable

section (as described in the next
chapter) into the cable clamp “D”.

– Connect the phase and earth cables

to the terminal block “B” according to
the diagram in figure 1.3.

– Pull the feeder cable and block it with

cable clamp “D”.

– Re-mount shield “A”.

N.B. The earth conductor must be left
about 3 cm longer than the others.

Fig. 1.2

D

B

A

230 V

PE

N

L

1

(L

2

)

Fig. 1.3

E

FEEDER CABLE SECTION
type H05RR-F

230 V

3 x 2,5 mm

2

(**)

(**) – Connection with wall box connection.

Advertising