INSTRUCTIONS FOR THE INSTALLER

Gas connection

Make sure that the appliance is adjusted for

the gas type available (see the label under the

appliance). Follow the instructions indicated in the

chapter “gas transformations and adjustments” for

the possible adaptation to different gases.

The appliance must be connected to the gas

system by means of stiff metal pipes or flexible

steel pipes having continuous walls, in compliance

with the regulations in force.

Some models are equipped with both cylindrical A

and conical B connectors for gas supply (fig. 7).

Please select the type which is correct for the

supply concerned.

The connection must not stress the gas ramp.

Once the installation is over, check the

connection seal with a soapy solution.

Electric connection

The connection to the electric grid must be carried

out by qualified personnel and in conformity with

the regulations in force.

The voltage of the electric system must correspond

to the value indicated in the label under the

appliance. Make sure that the electric system is

provided with an effective ground connction in

compliance with the regulations and provisions of

the law.

Grounding is compulsory.

This device must be at a suitable opening distance

from the contacts in order to allow the entire

disconnection in case of overvoltage category III,

in accordance with installation rules.

GAS TRANSFORMATIONS AND ADJUSTMENTS

Replacing the nozzles

If the equipment is adjusted for a type of gas that

is different from the one available, it is necessary

to replace the burner nozzles.

The choice of the nozzles to replace must be

made according to the table of the “technical

characteristics” as enclosed.

Act as follows:

-Remove the racks and burners.

-By means of a straight spanner L, unscrew

the nozzle U (fig.8) and substitute it with the

corresponding one.

-Tighten the nozzle strongly.

Adjusting the burners

The lowest flame point must always be properly

adjusted and the flame must remain on even if

there is an abrupt shift from the maximum to the

minimum position.

If this is not so, it is necessary to adjust the lowest

flame point as follows:

-start the burner up

-turn the tap up to the minimum position (small

flame)

-remove the knob from the tap rod

-introduce a flat-tip screwdriver in the hole F of

the tap (fig.9) and turn the by-pass screw up to a

proper adjustment of the lowest flame point.

As regards G30 gas burners, the by-pass screw

must be tightened completely.

MAINTENANCE

Replacing the power supply cable

If the power supply cable should be replaced,

it is necessary to use a cable with a section of

3x0.75mm

2

, type H05VV-F or H05RR-F, complying

with the regulations in force.

The connection to the terminal board must be

effected as shown in fig. 10-10/A:

brown cable L

(phase)

blue cable N

(neutral)

green-yellow cable (ground)