Troubleshooting 5.13 – Dometic RM 7401 L User Manual

Page 15

Advertising
background image

15

Troubleshooting

5.13

Failure : The refrigerator does not work in gas operation mode.

Possible cause

Action you can take

a.) Gas bottle empty.

b.) Is the supply cut-out device open?

c.) Air in the gas pipe?

Before calling the authorised Service Department, please check whether:

1. The instructions in the section "Using the refrigerator" have been followed.
2. The refrigerator is not tilted excessiveley.

3. It is possible to operate the refrigerator with an available power source.

Failure : The refrigerator does not work on 12V.
Possible cause

Action you can take

a.) On-board fuse defective.

b.) On-board battery discharged.

c.) Engine not running.

a.) Fit new fuse.

b.) Check battery, charge it

c.) Start engine.

Failure : The refrigerator does not work on 230V.
Possible cause

Action you can take

a.) On-board fuse defective.

b.) No connection to supply voltage.

c.) AES: gas operation despite connection

to the supply voltage?

a.) Fit new fuse.

b.) Establish power connection.

c.) Appliance switches to gas operation due to

insufficient supply voltage (automatically

switches back to 230 V operation)

Failure : The refrigerator does not cool sufficiently.

Possible cause

Action you can take

a.) Inadequate ventilation to the unit.

b.) The thermostat setting is too low.
c.) There is too much ice on the condenser.

d.) Too much warm food put inside.

e.) Appliance running for a short time.

a.) Check that the ventilation grilles are not

covered.

b.) Turn the thermostat to a higher setting.
c.) Check that the refrigerator door seals

when shut.

d.) Let food cool down first.

e.) Wait several hours, check again.

a.) Change gas bottle.

b.) Open the cut-out device.

c.) Switch device off and on again 3-4 times to

remove air from the gas pipe.

Advertising