D+ connection and solar control connection, Terminal strip, Retrofitting – Dometic RM 7401 L User Manual

Page 28

Advertising
background image

D+ connection and Solar Control connection

(only for RM 7XX5L appliances)

D+ connection

The D+ control connection must be connected to the respective vehicle
terminal (alternator signal while motor is running).

Solar control input (S+):

Connection only when using a solar system with a solar charging

controller with AES output.

The respective solar charging controllers are available from a specialized

dealer.

The “Solar” (S+) control connection must be connected to the respective

terminal of the solar charging controller (AES output).

Cable cross-sections

There are no particularly high current flows via the D+ and S+ connection;

therefore no particularly large cross-section is required for these connections

(approx. 1mm²).

Terminal strip (

RM 7XX1 L and RM 7XX5 L models

)

Retrofitting

28

Connections:

A = Ground heating element DC

B = Plus heating element DC

C = Ground electronics

D = Plus electronics

D+ = alternator signal

S+ = AES-input-control signal

(solar charge regulator)

A B

D+ S+

C D

- +

+

-

RETROFITTING

From the manual energy mode to the automatic energy mode

For all RM 7XX1 appliances (MES) there is an additional possibility for retrofitting

to an RM 7XX5 device with AES functions.
Please consult your nearest Dometic Customer Service or your specialist dealer.

on the vehicle

on the appliance

6.9.3

6.9.4

6.9.5

Advertising
This manual is related to the following products: