Cata ME 605 X User Manual

Page 39

Advertising
background image

Bars type 2

To remove the lateral guides take out the screw using a suita-

ble screwdriver, lift the bars upwards until they are free.

INSTRUCTIONS FOR INSTALLATION

This appliance must be installed by a competent person, in ac-

cordance with the current version of the UK Safety Rules and

Regulations or their European equivalent:

Urban development regulations (published by the Department

of Environment).

Urban development laws (published by the Scottish Executive

Development Department).

IEE wiring regulations.

Electricity in labour regulations.

PRIOR START-UP OF THE APPLIANCE

When it is unpacked, check that the following parts are with

the oven:

• Instructions and Installation Manual

• Oven grid

• 1 tray

• Screws and stoppers for fitting the appliance in the housing

FITTING THE APPLIANCE (see Fig. 5)

These appliances are classified as Class I.

The earth is obligatory as provided for by law. The manufactur-

er declines all liability in the event that the accident prevention

rules have not been followed.

IMPORTANT

The adjacent piece or furniture or cupboard and all the materi-

als used in the installation must resist a minimum temperature

increase of 85 ºC above the ambient temperature during use

of the appliance.

Certain types of vinyl or laminated kitchen furniture are par-

ticularly susceptible to damage due to decolouration at tem-

peratures below those indicated.

If the appliance is installed without paying attention to this

temperature limit or if it is placed less than 4 mm from the adja-

cent cupboards, liability will belong to the owner.

INSTALLATION NOTES

1. The oven has to be installed in a standard gap of 600mm, as

indicated in Fig. 5, whether under a hob or in a column.

2. On inserting the oven in a column, it is essential in order to

ensure there is enough ventilation, to remove the rear panel

of the furniture and have an opening of at least 85-90mm as

indicated in Fig. 5.

3. Check that the oven has been fixed securely in the housing.

Fixing the oven into the cupboard is done using 4 screws “A”

Fig.5. One in each corner of the oven door frame.

Fig. 5: Installation distanced for simple electric ovens of 60 cms

wide (the shape of the upper casing may vary) and attachment

to the cupboard.

BUILT IN DIMENSION FOR OVEN WITH DOOR THICKNESS OF

26mm (dim A)

Advertising
This manual is related to the following products: