Wiring, Le-1 series installation guide v2.0 3, Le-1 – Cloud Electronics LE-1MB User Manual

Page 3

Advertising
background image

LE-1 Series Installation Guide v2.0

3

PIN

USE

CAT-5 CORE

1

Left (cold)

White + Orange

2

Left (hot)

Orange

3

Sense

White + Green

4

DC +ve

Blue

5

0v

White + Blue

6

DC -ve

Green

7

Right (hot)

White + Brown

8

Right (cold)

Brown

SCN

Screen

Connector Shell

1

8

1

8

1

8

1

8

Wiring

The LE-1’s OUTPUT connector should be connected to one of the DCM1’s EXTENSION PORTs (Line inputs 1 to 4) with screened
Cat 5 cable and shielded RJ45 plugs. Do not connect any other equipment to the phono sockets of the same-numbered Line Input
on the DCM1.

Connect to

Output socket

Screened

Cat 5 cable

LE-1

OUTPUT

LINK

LE-1

(UK version illustrated)

MICROPHONE INPUTS

EXTENSION PORTS

DCM1

1

2

3

4

1

2

3

4

Connect to an

unused Extension Port

Note that all LE-1s have two RJ45 connectors, OUTPUT and LINK. These are both mounted on the lower PCB, with the OUTPUT
connector on the right (looking at the module rear), and the LINK connector on the left.

IMPORTANT: Because the cables carry low-level audio, only screened Cat 5 should be used, the foil screen of the cable being
bonded to the metal screening can of the plugs. If an LE-1 is being mounted in close proximity to the DCM1, it may be possible to
use ready-made screened Cat 5 “patch” cables of an appropriate length. Otherwise, shielded RJ45 plugs should be crimped onto
the installed screened Cat 5 cable using the pinout shown below.