Connecting multiple me-1s, Me-1 installation guide v1.0 3, Me-1 – Cloud Electronics ME-1 Installation User Manual

Page 3

Advertising
background image

ME-1 Installation Guide v1.0

3

Connect to

Output socket

Screened

CAT-5 cable

Microphone Inputs

Extension Ports

DCM-1

1

2

3

4

1

2

3

4

Connect to an

unused Microphone Input

ME-1

OUTPUT

LINK

PIN

USE

CAT-5 CORE

1

Mic sum (cold)

White + Orange

2

Mic Sum (hot)

Orange

3

Sense

White + Green

4

DC +ve

Blue

5

0v

White + Blue

6

DC -ve

Green

7

n/u

White + Brown

8

n/u

Brown

Connecting Multiple ME-1s

Multiple ME-1s may be “daisy-chained” together to provide additional input points,
normally in the same zone. Signals applied to plates wired in this way will be summed

together to the DCM-1 Microphone Input to which the “last” ME-1 in the chain is
connected. An internal gating circuit on each plate automatically “disconnects” any

chained plates which are not in use, to minimise noise contribution. All microphones
plugged into ME-1s on such a chained system will be summed together into one mono

signal.

Multiple ME-1s may be daisy-chained together by connecting the LINK RJ45 socket on
the first ME-1 (that whose OUTPUT socket is connected directly to the DCM-1) to

the OUTPUT socket on the second ME-1, and so on, as shown on page 4.

1

8

1

8

1

8

1

8

Advertising