Channel selection, Table 6-1: channel selection settings – Codan Radio MT-4R User Manual

Page 47

Advertising
background image

UG-001 Daniels MT-4R and MT-4D Radio Systems

www.danelec.com

Chapter 6: Radio System Components

39

User

Guide

Channel Selection

Daniels P25 radio modules are capable of 16 channel operation in 2 banks (32 channels total). The
16 channels are controlled via 4 CSEL signal lines connected to each receiver and transmitter module.
The CSEL signal lines are set as either a 0 (0 Vdc) or a 1 (+9.5 Vdc). Table 6-1 shows the channel
selected for the CSEL input settings.

Table 6-1: Channel Selection Settings

Channel

Decimal

CSEL3

CSEL2

CSEL1

CSEL0

1

0

0

0

0

0

2

1

0

0

0

1

3

2

0

0

1

0

4

3

0

0

1

1

5

4

0

1

0

0

6

5

0

1

0

1

7

6

0

1

1

0

8

7

0

1

1

1

9

8

1

0

0

0

10

9

1

0

0

1

11

10

1

0

1

0

12

11

1

0

1

1

13

12

1

1

0

0

14

13

1

1

0

1

15

14

1

1

1

0

16

15

1

1

1

1

The Receiver and Transmitter Bank A/B select lines normally fl oat high (+5V), selecting Bank A, but
may be pulled low or high externally via the Bank A/B select line. The Receiver Bank A/B select line
uses the same line as the MT-3 Receiver ISO COR K and the Transmitter Bank A/B select line uses the
same line as the MT-3 Transmitter Standby.

There are 3 different ways to change the channel of a transmitter / receiver module:

1

The user can set jumpers mounted on the motherboard for each Channel Select signal line (Set
of four for each Tx / Rx module). These jumpers can be used to permanently set a subrack slot
at a specifi c channel.
- Jumpers can be set for 0 (0 Vdc) “down” or 1 (9.5 Vdc) “up”
- Pull-up resistor jumpers to 9.5 Vdc must be installed
- These jumpers are read right to left (MSD to LSD)

2

CSEL signal lines can be controlled externally by a tone remote adapter, a CI-RC-4M multiple link
controller, or other third party devices.

3

16 position rotary select switches mounted on the front of the base controller can control the
CSEL lines, and optionally the CI-RC-4L repeater controller can have a rotary switch added.

The pull-up resistor jumpers to 9.5 Vdc must be removed and all channel select jumpers must be
installed in the 1 or “up” position for both external control and rotary switch control of channel selection.
The locations of the channel select and pull-up jumpers are shown in Figure 6-3.