Temperature monitoring, Foam tape installation, Drilling installation – CompX eLock Temperature Monitoring Programming User Manual

Page 6

Advertising
background image

Temperature Monitoring

The CompX eLock

®

assembly (body) can be mounted to the front of the refrigerator

either by using foam tape or by drilling holes.

Foam Tape Installation

Please note that if foam tape installation of the strike is used,
the main CompX eLock

®

will

not

be adjustable once it's put in place.

a. Install one piece of double-sided tape on each side
of the CompX refrigerator eLock assembly.
b. Remove liner from double-sided tape.
c. Carefully press CompX eLock

®

onto the center of the strike.

Drilling Installation

a. Click CompX eLock

®

onto strike.

b. Push assembly up and center it on the strike.
c. Drill six 9/64" holes through the housing into the refrigerator door
for the mounting screws. Secure with screws.

note:

Top two screws may

be omitted if they interfere with door handle access.

note:

If foam tape was used to mount the strike, the CompX eLock

®

refrigerator kit

installation is COMPLETE. The CompX eLock

®

may now be used.

Mount the main compX elock

®

body to the refrigerator door

Step

3:

a. Remove the plastic cover from the strike plate. Drill 9/64" hole
in second opening of strike.

b. If adjustment of strike is needed, loosen up the first strike
screw and adjust the strike. Tighten up the screw.

c. Drill hole for second screw and install second screw.

d. Reattach the plastic strike cover and attach with two
tamper resistant machine screws.

finish installation of the strike (only if drilled installation of strike was used)

Step

4:

6