Comtech EF Data CDM-750 User Manual

Page 220

Advertising
background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Serial-based Remote Product Management

MN-CDM750

7–40

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Rx BERT

Pattern

RBP=

1 byte, value

of 0 thru 6

Command or Query.

Set or return the PN loopback pattern type in the form x, where:
0 = 2^23-1
1 = Reserved

2 = Reserved
3 = Reserved

4 = Reserved
5 = 2047

6 = 2^15-1

Example: RBP=0 (default 2^23-1)

RBP =

RBP?
RBP *
RBP #

RBP?

RBP =

(see Description of
Arguments)

Tx BERT
Pattern

TBP=

1 byte, value
of 0 thru 6

Command or Query.
Initialises the PN loopback functionality and sets the pattern type in the form x, where:
0 = 2^23-1

1 = Reserved
2 = Reserved

3 = Reserved
4 = Reserved

5 = 2047
6 = 2^15-1


Example: TBP=0 (default 2^23-1)

TBP =
TBP?
TBP *

TBP #

TBP?

TBP =
(see Description of
Arguments)

BERT Error
Insert

BKE=

None

Command only.
Inserts a single error.

BKE =
BKE?

BKE #

N/A

N/A

BERT Clear
BER Counters

BRM=

None

Command only
Clears the BER counters.

BRM =
BRM?

BRM *
BRM #

N/A

N/A

BERT Results
All: Total Bit

Errors, Total
Number Of

Bits and
average BER

N/A

22 bytes

Query only.
Returns 3 values, with each parameter is separated by a colon, in the form x.xEx:y.yEy:z.zEz where:

x.xEx = total number of bit errors
yEy = total number of bits

z.zEz = value of the average BER or “No Sync” if no demod lock.

Example 1: BRA=1.0E+03:2.2E+06:1.0E+03 (No Demod Lock)
Example 2: BRA=1.0E+03:2.2E+06 (No Sync)

N/A

BRA?

BRA=x.xEx:y.yEy:z.z
Ez

(see Description of
Arguments)

Tx BERT

State

BTX=

1 byte, value

of 0 or 1

Command or Query.

Set or return Tx BERT state in the form of x, where:
0 = off
1 = on


Example: BTX=1 (BERT On)

BTX =

BTX?
BTX *
BTX #

BTX?

BTX =x

(see Description of
Arguments)

Advertising