4 performing the ethernet ftp upload procedure – Comtech EF Data CDM-750 User Manual

Page 74

Advertising
background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Updating Firmware

MN-CDM750

4–8

• Type  “dir”  to  list  the  files  extracted  to  the  temporary  directory  from  the 

downloaded archive file. 

 
The firmware files have been successfully downloaded and are now available for transfer to 
the CDM‐750.
 

4.4

Performing the Ethernet FTP Upload Procedure

 

To proceed with the firmware update procedure, assumptions are made that: 
 

The CDM‐750 is connected to a user‐supplied, Windows‐based PC, and: 

 
o The PC serial port is connected to the CDM‐750 ‘J3 | REMOTE’ port. 

 

o The  PC  Ethernet  port  is  connected  to  the  CDM‐750  ‘J4  |  MGT’  10/100 

BaseT  Ethernet  port  with  a  user‐supplied  hub,  switch,  or  direct  Ethernet 
cable connection. 
 

o The  PC  is  running  a  terminal  emulation  program  (for  operation  of  the 

CDM‐750  Serial  or  Telnet  Remote  Interfaces)  and  a  compatible  Web 
browser (for operation of the CDM‐750 Web Server Interface). 

 

The CDM‐750 Management IP Address has been noted, and the firmware has 

been  identified  using  the  Front  Panel,  the  Remote  Interface,  or  the  CDM‐750 
Web Server Interface ‘Status | Firmware’ page. 

 

The  latest  firmware  files  have  been  downloaded  or  otherwise  received  from 

Comtech EF  Data and are available on the user PC in an accessible temporary 
folder. 

 

NOTE THAT CONDITIONAL FIRMWARE UPDATE REQUIREMENTS APPLY. 

 

If you are currently running Firmware Ver. 1.4.4 or earlier, before updating your 
unit  with  Firmware  Ver.  1.6.0  or  newer  you  must  first  update  your  unit  with 
Firmware Ver 1.5.1. If your currently  running Firmware is Ver.  1.5.1 or 
newer
this step is not necessary. Note that Firmware Ver. 1.5.1. is a gateway load that 
allows firmware versions newer than Ver. 1.4.4 to be loaded onto a CDM‐750 – 
otherwise, Ver. 1.5.1 is  identical in functionality to Firmware Ver. 1.4.4.
 

 
1. Use  Command‐line  to  send  a  “PING”  command  to  confirm  proper  connection  and 

communication between the user PC and the CDM‐750: 

 

If the Management IP Address of the unit is still not known, obtain this information via 

one of the following methods: 
 
o Using the CDM‐750 Front Panel Keypad / VFD – Review the information provided 

on the SELECT: Configuration Æ IP Æ Addresses Æ Add/Range screen. 