G–25

On the bottom line: Use the

◄ ►

arrow keys to select the operating frequency for Side B:

C, X, Ku, or Ka-band.

Press ENTER when done.

For the CDM-570A only: On the top line, use the ▲▼arrow keys to select the specific CnC-

APC mode – the screen appearance updates accordingly:

Mode: APC,Side-A, C-band

Act?N APC is not active

Press ENTER after selecting the Side A frequency, and then repeat the process to select the

Side B frequency. Do not select Act? (Activate) as Y (Yes) at this time. Note the following:

• If Side A is selected at both sides, or Side B is selected at both sides, both modems

will display a Frame Sync fault (under Rx faults). No further action is possible until

this error has been corrected.

• If different satellite bands are selected on each side (for instance, Side A is Ku-Band,

while side B is C-Band) the modem will display an APC Band Mismatch fault (under

Rx faults). No further action is possible until this error has been corrected.

Based on the known RF terminal equipment in use, determine a value for the maximum

allowed power increase (TPLI

max

) and then set this value. From the CDM-570A front panel,

select the CONFIG Tx Pwr menu:

Output Power Level Mode:

Manual AUPC CnC-APC

With APC mode activated, CnC-APC is the only selectable mode. Press ENTER to continue to

edit the Tx Pwr Level:

Tx Pwr Level: -35.0dBm

Max Pwr increase: 2.5dB

To edit the power output level and the maximum permitted increase in power level when

in CnC-APC Mode: On the top line, use the

▲▼

arrow keys to select the value (in dB) as

-00.0, -10.0, -20.0, or -25.0. Press ENTER when done.

Note that when APC is in an active state, the power level on the bottom line will read

‘AUTO’.

5) Go back to the SELECT: CONFIG: CnC MODE menu.

For the CDM-570AL only: On the bottom line, select Action and then press ENTER. Then,

use the

◄ ►

arrow keys to select select Activate.

CnC Mode: Off On APC

Action (◄ ►,ENTER)

CnC-APC:Activate Suspend

APC is not active

Press ENTER when done.