Comtech EF Data CRS-500 User Manual

Page 179

Advertising
background image

CRS-500 1:N Redundancy System

Revision 2

Serial-based Remote Product Management

MN-CRS500

9–19

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that

is, ASCII codes between 48 and 57)

Response to Command

(Target to controller)

Query

(Code and

qualifier)

Response to query

(Target to controller)

Retrieve Next 5

unread Stored

Events

N/A

80 bytes

Query only.

Returns the oldest 5 Stored Events that have not yet been

read over the remote control in the form

[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-

body, where:

Sub-body = KLMddmmyyhhmmss, where:

K is the fault/clear indicator, where

F = Fault, C = Clear, I = Info

L is the faulting/clearing unit, where the values can be:

1,2,...9 indicating traffic modems 1,2...9;

A=modem 10

B=Redundant Modem

C=Switch

D=Info

M is the fault code, where value depends on faulting unit:

Switch codes are 1 to F, indicating the position (1-15) of

the fault within the Switch FLT string.

Modem codes are:

1= Unit, 2= Rx traffic, 3= Tx traffic

Info codes are:

0= Power off, 1= Power on, 2= Log cleared

ddmmyy is the date of the event (international format).

hhmmss is the time of the event.

Notes:

1. If there are no new events, the unit replies with RNE*.

2. If fewer than 5 events remain, the last positions are

filled with zeroes.

N/A

RNE?

RNE=[cr]KLMddmmyyhh

mmss[cr]KLMddmmyyhh

mmss[cr]KLMddmmyyhh

mmss[cr]KLMddmmyyhh

mmss[cr]KLMddmmyyhh

mmss

(see description of

arguments)