Hpcst-5000 specifications, Prime power specification, System interfaces – Comtech EF Data HPCST-5000 User Manual

Page 31: 2 system interfaces

Advertising
background image

High Power C-Band Satellite Terminal

Introduction

Rev. 0

1–15

1.7 HPCST-5000

Specifications

1.7.1

Prime Power Specification

Refer to Table 1-5 for prime power specifications.

Table 1-5. Prime Power Specifications

Assembly

Ref Des

Option

Prime Power/Power Consumption

RFT-500

J5

AC

90 to 265 VAC, 47 to 63 Hz, 90W

SSPA-500:

75W
100W
125W
150W

J5
J5
J5
J5

AC
AC
AC
AC

Prime Power/Power Consumption
90 to 265 VAC, 47 to 63 Hz, 500W
90 to 265 VAC, 47 to 63 Hz, 700W
90 to 265 VAC, 47 to 63 Hz, 800W
90 to 265 VAC, 47 to 63 Hz, 1000W

LNA

DC

10.8

# 0.2 VDC (as provided from RSU)

RSU-503L

J4, J8

DC

10.8 VDC (from either RFT-500)

1.7.2 System

Interfaces

Refer to Table 1-6 for system interfaces on units.

Table 1-6. System Interfaces on Units

Description

Type

RFT-500:

TX IF Input (J1)
RX IF Output (J3)
RX RF Input (J4, C-Band)
TX RF Output (J2, C-Band)
M&C Control (J6)

TNC female, 50

$, VSWR 1.5:1 maximum

TNC female, 50

$, VSWR 1.5:1 maximum

N, female, VSWR 1.5:1 maximum
N, female, VSWR 1.5:1 maximum
Circular, PT06E-16-26S

SSPA-500:

RF TX Output (W/G)
RF TX Input (J1, C-Band)
RF TX Monitor (J4, C-Band)
M&C Control (J3)

CPR-137G, VSWR: 1.25:1 maximum
N, female, VSWR 1.25:1 maximum
N, female, VSWR 1.3:1, typical 40 dB coupler
Circular, PT06E-16-26S

LNA:

RF RX Input (W/G)
RF RX Output (2X)
1:1 Switch Control

CPR-229G, VSWR: 1.25:1 maximum
N, VSWR 1.5:1 maximum., female
Circular, PT06E-14-19P

Advertising