Terminal default conditions, Theory of operation, 1 remote interface specification – Comtech EF Data KST-12025 User Manual

Page 90: 3 terminal default conditions, 4 theory of operation

Advertising
background image

Theory of Operation

KST-12025 Ku-Band Satellite Terminal

5–4

Rev. 1

5.1.2.1

Remote Interface Specification

Refer to Appendix A.

5.1.3

Terminal Default Conditions

On initial power-up, the unit will default to the following parameters.

Parameter

Default

Baud Rate

[9600]

Parity

[Even]

Device Address

[1]

U/C Gain

[10.0]

D/C Gain

[0.0]

RF Output

[OFF]

U/C Frequency

[Low end of range]

D/C Frequency

[Low end of range]

5.1.4

Theory of Operation

Refer to Figure 5-3 for a functional block diagram of the M&C.

The M&C PCB performs the following operations:

Receives the desired frequency from either the remote EIA-232-C/485 or local
keypad, and after converting it to a synthesizer setting, stores it to the applicable
synthesizer output latch.

Reads the thermistors located in the up converter, down converter, and high-
power amplifier, and converts them to temperatures for display.

Reads the characterization EEPROMs in the up converter, down converter, and
high-power amplifier, and calculates an Automatic Gain Control (AGC) voltage
based on frequency and temperature to linearize the respective module.

Turns the fan on or off, depending on the temperature.

Receives fault inputs from all modules, and presents them to the remote EIA-
232-C/485 and the optional local keypad display.

Performs an initial current sense on the LNA, and stores the reading in
EEPROM. Subsequent current sense readings are taken and compared to the
initial reading to determine a fault.