3 servicing with power on – Comtech EF Data RSU-503 User Manual

Page 48

Advertising
background image

RSU-503 Redundancy Switch Unit

Maintenance

Rev. 8

4–3

4.3 Servicing with Power On

If maintenance must be performed on the unit while the link remains on the air, proceed
as follows:

1. Loosen the access panel screws on the side of the switch case (refer to

Figure 4-2) to expose the internal M&C Logic Control PCB.

Figure 4-2. Access Panel

2. Observe the LEDs on the M&C board, which will indicate the following:

a.

Receipt of power from RFT A

b. Receipt of power from RFT B
c.

Transfer switch power (32V) available

d. Summary fault indicator, if any fault in the system
e.

Uplink RFT, Unit A fault

f.

Uplink RFT, Unit B fault

g. Uplink Indicator Ambiguity fault
h. Uplink unit A or B currently online
i.

Uplink mode in Auto or Manual

j.

Downlink RFT, Unit A fault

k. Downlink RFT, Unit B fault
l.

Downlink Indicator Ambiguity fault

m. Downlink unit A or B currently online
n. Downlink mode in Auto or Manual

3. Refer to Section 4.4 for troubleshooting assistance.