Comtech EF Data NetVue Release 1.1 Provisioning Guide User Manual

Page 13

Advertising
background image

MN-NETVUEPVG or CD-NETVUEPVG

Revision 1

NetVue Provisioning Guide

Release 1.1

11

Reference: name of a Network View where the site appears in the NetVue. It must be an existing
view of which the new View or in which the new Circuit (as part of the Network – see below) will
be created

Network: the network where the equipment in question is to be created/removed or otherwise
affected (sometimes this Provisioning Tool may be used to change equipment’s configuration in
the NetVue)

Circuit: the name of the circuit the equipment is to be assigned to

Longitude: where the equipment is assigned – this results in the placement on the map view

Latitude: where the equipment is assigned – this results in the placement on the map view

Protocol: this is the driver protocol that is used to communicate with the equipment. This is a
dropdown selection list

Equipment: name of the equipment. Has significant effect on the NetVue Search usability. The
more descriptive this field is, the easier it is going to be finding relevant devices in the NetVue.
MUST be unique in the NetVue System/Cluster. This field has maximum length of 200 ASCII
characters.

NOTE: Do not use these characters:
( \ / : * ? “ < > | ° ; )

Equipment Position: the placement of the equipment within the circuit view. If the specified device
is not part of Circuit (for example non-CEFD device in the HUB) this field becomes irrelevant.
Runs horizontally from 0 to 6 and vertically positions A, B (or no specific letter use for middle line)
– these values dictate where the images fall on the circuit view as shown in Figure 4 Circuit View
Positions.

Local/Remote: the placement of the equipment within the circuit view. Signifies equipment
collocated at the Hub vs. equipment located at the remote facility/installation.

IP Address: the IP address of the actual equipment or IP address of the adapter/gateway/protocol
convertor.

IP Port: 161 for direct SNMP management device or port number mapping for IP to serial
gateway

EDMAC: if the device is a serial device with EDMAC capability, enter the EDMAC address

Redundancy Device Port: the port of the redundant device (if available). Relevant only for CRS-
x00 device

TX Frequency (MHz): The center frequency (IF, L-band) to be programmed into the Spectrum
Analyzer in order to appear in the thumbnail Spectral view of the TX signal in the Circuit View

RX Frequency (MHz): The center frequency (IF or L-band) to be programmed into the Spectrum
Analyzer in order to appear in the thumbnail Spectral view of the RX signal in the Circuit View.