Cybex 20000 Eagle NX Chest Press User Manual

Page 12

Advertising
background image

Cybex Owner’s Manual

12

3. Remove BHSCS and pulley shaft bolts securing lower pulley assembly to pulley bracket

using two 5/16” Allen wrenches.

2
3

4

1

Description

1 Pulley shaft bolt
2 BHSCS
3 Lower pulley assembly
4 Pulley bracket

4. Remove pulley assembly from pulley bracket.
5. Route cable up through top cover, guide rod plate, and pulley bracket.
6. Set cable aside for rerouting.

Remove weight plates

1. Turn the increment weight adjusting knob to select 0 lbs (0 kg).
2. Remove four Phillips head screws and plastic mount for guide rod access.

3

4

1

2

Description

1 Phillips head screw (4)
2 Plastic mount
3 Top guide rod cap (2)
4 Guide rod (2)

3. Remove top guide rod caps. Top guide rod cap contains a compression spring that will fly if

grasp is not released slowly. Slide spring loaded top guide rod cap down guide rod until cap

is clear of frame. Slowly release grasp of top guide rod cap and set aside.

4. Repeat above step for opposite guide rod.
5. Lean guide rods slightly outward, away from machine. DO NOT put excessive pressure on

guide rods, it will damage lower guide rod caps.

6. Slide top weight up and out of the machine and set aside.
7. Remove weight plates and set aside for reinstallation later.

Advertising