7 signal termination from computer to display, Signal termination from computer to display -7 – Daktronics AF-3300-12-RGB/20-R User Manual

Page 25

Advertising
background image

Electrical Installation

3-7

The disconnecting means must be located in a direct line of sight from the display or
outline lighting that it controls. This requirement provides protection by enabling a
worker to keep the disconnecting means within view while working on the display.

Exception: Disconnecting means that are capable of being locked in the open
position may be located elsewhere.





3.7 Signal Termination from Computer to Display

The AF-3300 is designed for quicker signal and power connection to the display and
between displays.

• Signal will terminate to a watertight enclosure, which connects to the

primary display using a quick connect cable

• Mounting the temperature sensor to the display structure and at least one

foot away from the display is preferred – terminate it to the primary display
with a quick connect cable (Do Not mount the temperature sensor between
display, or anywhere that the airflow is restricted)

• The primary display will connect to the mirror display (2V installations)

with a 6-foot, quick connect, inter-connect cable. In the case of those cables
that have right-angle connector, make sure the cable extends to the side or
down (never up) to prevent stress on the cable

A separate manual is provided for explaining the connection to the signal termination
enclosure. There are seven different methods of communication; your manual will be
one of these types:

Communication Type

Communication Manual ED #

RS232 ED-14739

RS422 ED-14742

Fiber ED-14743

Radio ED-13932

Modem ED-14744

Ethernet ED-14745

Fiber Ethernet

ED-14746