Figure 23: 120/240 v power termination, Figure 24: 240 v power termination – Daktronics AF-3700-20 RGB User Manual
Page 25
For 16-high displays:
Terminating hot, neutral, and ground wires at the J-box
1. Route the power cable through ½” conduit to the rear of the display and into the power
termination J-box.
2. The power termination enclosure will contain two or three wires plus a ground coming
from the interior of the display. These wires are pre-terminated to the power termination
panel inside the display.
3. Inside the external power termination J-box, connect the power wires to the wires coming
from the display interior using wire nuts. Refer to Figure 23
for 120/240 VAC and Figure
24 for 240 VAC.
Note the following colors are used for the pre-terminated wires:
120/240 VAC
240 VAC
• Line 1 – Black
x
Line 1 - Brown
• Line 2 – Red
x
Neutral - Blue
• Neutral
-
White
x Grounding – Green-Yellow
• Grounding – Green-Yellow
Figure 23: 120/240 V Power Termination
Figure 24: 240 V Power Termination
Power Installation
15