Figure 23: 120/240 v power termination, Figure 24: 240 v power termination – Daktronics AF-3700-20 RGB User Manual

Page 25

Advertising
background image

For 16-high displays:

Terminating hot, neutral, and ground wires at the J-box

1. Route the power cable through ½” conduit to the rear of the display and into the power

termination J-box.

2. The power termination enclosure will contain two or three wires plus a ground coming

from the interior of the display. These wires are pre-terminated to the power termination
panel inside the display.

3. Inside the external power termination J-box, connect the power wires to the wires coming

from the display interior using wire nuts. Refer to Figure 23

for 120/240 VAC and Figure

24 for 240 VAC.

Note the following colors are used for the pre-terminated wires:

120/240 VAC

240 VAC

• Line 1 – Black

x

Line 1 - Brown

• Line 2 – Red

x

Neutral - Blue

• Neutral

-

White

x Grounding – Green-Yellow

• Grounding – Green-Yellow

Figure 23: 120/240 V Power Termination

Figure 24: 240 V Power Termination





Power Installation

15

Advertising