Troubleshooting Checklist – Data Distributor Displays

If the display has a data distributor, the following table covers a few possible problems that you may
encounter while operating the display, along with a cause/solution. While this list does not cover
every possible problem, it does list those that are most likely to occur.

Problem

Possible Cause/Solution

One or more lamps will not light.

=

Replace the lamp.

=

Replace the socket.

=

Replace the lampbank

One or more lamps will not turn off.

=

Check for metallic foreign objects on
the lampbank causing a short.

=

Check for foreign objects on PC
board.

=

Replace the lampbank

All of one row of modules across the
entire display is not working.

=

Check output card at data distributor.

=

Replace output card at data
distributor.

=

Check signal cables to first column
director in that row.

=

Replace column director.

A section of the display is not working
(multiple rows in a group up to 4
modules long.)

=

Check signal cables to the column
director for that section.

=

Replace the column director.

A row of modules up to 4 modules long
is not working.

=

Check the signal cable to the line
controller in that row.

=

Replace the line controller.

Garbled display or shifted sequence.

=

Check RJ45 network cable.

=

Check output on data distributor
output card.

=

Set computer and line receiver to high
line feed.

Single module does not work

=

Check signal connection (ribbon
cable).

=

Check power connections.

=

Check appropriate breaker in
panelboard.

=

Check in-line transformer fuse.

=

Replace lampbank.

Entire display does not respond to any
source of data.

=

Check clear LED on receiver board (if
red, data distributor is not getting
signal)

=

Controller may be off

=

Fiber optic connection may be bad or
broken

Display works for a short time and then
blanks.

=

Check that all fans are operational
and running at full RPM.

=

Check that filters are not plugged and
limiting airflow.