Re-Calibrating Your Scale

D3924

SLC 2400 Operator’s Manual

19

RE-CALIBRATING YOUR SCALE

To re-calibrate your scale and make it even more accurate, document

several loads of varying sizes and measure the actual weight of all

loads on a certified scale.

In this example, we are unloading six loads onto four semi-trucks.

Example:

Load A

51560

Load B

33240

Load C

17620

Load D

50420

Load E

38200

Load F

12360

Total

Indicator Weight

203400

Truckload #1

51920

Truckload #2

51320

Truckload #3

50720

Truckload #4

51070

Total Certified Weight

205030

Reading Too High

If the Indicator is reading higher than the certified scale, then the

calibration number is high and should be decreased proportionally. See

page 20.

Reading Too Low

If the Indicator is reading lower than the certified scale, then the

calibration number is low and should be increased proportionally. See

page 20.