Menus and Calibration

D3715 Rev D

EZ3600 User’s Manual

35

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

REMOTE DISPLAY

(RMDISP)

234

Select type of remote

display

MENU 3. SCALE CALIBRATION SETTINGS

DISPLAY UNIT

(lb-kg)

303

LB

/KG

Display pounds -lb or

kilograms -kg

MIMIC TYREL

(tcI300)

321

OFF

/ON

If ON -records preset

weights like a TYREL

TCX-1300 indicator.

Indicator Tracks gross

weight while batching.

MENU 4. PRESET, BATCHING & ROTATION COUNTER FEATURES

PRE ALARM

(p mthd) & (p-alm)

401

WEIGHT

PERCNT

Select weight or

percentage method, then

enter a value to activate

an early warning that

indicator is reaching the

preset.

BUZZER

(buzzer)

404 1-4,

ON

/OFF

ALARM BUZZER -allows

user to turn off alarm

horn.

TIMER/

COUNTER

(tmrctr)

421

REV

TIME

Select time or mixer

revolutions to decrement

mix timer/counter.

DRIVE RATIO

(dratio)

422

0001.00

Enter the number of input

pulses that equal 1 mixer

revolution.

MANUAL

PROGRAMMING

(Program)

439

PC

/SCALE

PC: Requires a Datakey

with programming.

Scale: Allows user to

manually program

indicator.

ENTRY METHOD

(E MTHD)

441

1

,2,3

Select batch 1-

amount/animal

2-percent/load

3- amount/load

TOLERANCE

(toler)

442

OFF

,.5,1-5,7,10

Select tolerance weight

percentage to accept

ingredient.

INGR. ADVANCE

DELAY

(delay)

443

MANUAL

, 1-3,5,7,

10,20,30,60

Select seconds to delay

before advancing to next

ingredient.

FORCE USER ID

(userid)

446 ON/

OFF

If ON -operator must enter

user ID to use indicator.

Advertising