Menus and Calibration

36

EZ3600 User’s Manual

D3715 Rev D

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

RESIZE RECIPE

(resize)

448

ON

/OFF

If ON -operator can

change recipe size.

RECIPE TOTAL

(rectot)

451 ON/

OFF

Selects total amount to be

displayed when starting

recipe.

TOLER OVER

LOCK

(overlk)

453 ON/

OFF

If ON -prevents auto-

advancing if preset

exceeds tolerance

FEED ZONE

(fdzone)

454

ALL

, 1-9

Select feed zone for

recipe deliveries.

UNDONE RECIPES

(undn I)

455 ON/

OFF

If ON -displays all

incomplete recipes or

enable if indicator is

stationary mixer/batch

when using Datalink.

AUTO START

PENS

(autpen)

458 ON/

OFF

If ON -starts pens list after

recipe is loaded in list

mode format.

MANUAL PEN

ADVANCE

(manpen)

461

ON

/OFF

If ON -overrides automatic

advance for pens.

PEN TOL

(t mthd} & {pentol)

462

WEIGHT

PERCNT

Select weight or

percentage method, then

enter pen tolerance.

PEN WEIGHT

(pen wt)

463

LOAD

GROSS

NET

Select method for

displaying pen Weight -

net, load, or gross.

DOUBLE KEY

PRESS PREV

(dbkey)

465 ON/

OFF

Select method ignores

double pressing of keys

when advancing ingr.

while loading mixer.

RECIPE REMAIN

ACTIVE

(RE-USE)

466

ON

/OFF

Select ON to reuse

recipes.

CALIBRATION

SETUP NUMBER

(SETUP)

871

Quick entry method

selects weigh method 1-

4lbs, 5-8 kg, gain 1-9,

display counts 1-9 and

capacity *1000

CALIBRATION

NUMBER

(CAL)

872

Weight displayed at

0.4mV/V for these load

cells